FC04

Wolf Fehlercode FC04.

BEDEUTUNG

A fault shutdown can be triggered by aged or low-capacity motor capacitors (especially plastic versions). To prevent this, a plastic capacitor should be replaced by an aluminum capacitor; for aluminum capacitors, the capacity must be checked.

HÄUFIGE URSACHEN

  • Plastic capacitor in the oil pump motor with decreasing capacity due to aging
  • Aluminum capacitor with capacity drop below the limit value
  • Insufficient motor start of the oil pump due to capacitor damage

TYPISCHE ERSATZTEILE BEI FC04

Oil pump motor capacitor 89 08 533

Erst messen, dann tauschen: Die App führt dich durch die Prüf-Reihenfolge, bevor du Teile bestellst.

ERSTE PRÜFSCHRITTE

  1. 1.De-energize the system and check for absence of voltage; secure against re-energization.
  2. 2.Pull the burner plug from the central connector.
  3. 3.Remove the protective cap on the capacitor.
In der App enthalten
  • 5 weitere Prüfschritte in der richtigen Reihenfolge
  • Prüf-Reihenfolge vor dem Teiletausch (spart Fehlkäufe)
Kostenlos freischalten →
Stehst du gerade vor der Anlage? (Wolf FC04)

Öffne myHVACPro und dokumentiere Diagnose und Reparatur direkt im Einsatz: kompletter Prüfpfad zu FC04 mit Soll-Messwerten, Foto-Doku — und in Minuten ein sauberer PDF-Servicebericht für den Kunden.

Inklusive 7 Tage Pro gratis — ohne Kreditkarte, endet automatisch.

FRAGEN & ANTWORTEN AUS DER PRAXIS

Noch keine Fragen zu diesem Fehlercode. Stelle die erste — Techniker-Kollegen und unser Team antworten.

Offizielle Unterlagen: Wolf Service & Downloads ↗

WEITERE WOLF FEHLERCODES

Hinweis: Arbeiten an Gas-, Öl- und Elektroinstallationen dürfen nur durch qualifiziertes Fachpersonal durchgeführt werden. Alle Angaben ohne Gewähr — maßgeblich sind die Herstellerunterlagen.